PS-1872 - Digital Power PS-1872 Power Supply - High Voltage Power Supply...
Request Quote
For Price
- Part Number:
- PS-1872
- Model Number:
- PS-1872
- Make:
- DIGITAL POWER
- Lead Time:
- Available
- Qty In Stock:
- Available
Digital Power PS-1872 Power Supply - High Voltage Power Supply 325 VDC 72 KW 24-U 19 in. AC-DC Front End Power Rack Simple Type: Power Supply Plug-In Module
The Digital Power PS-1872 is a high power, high voltage power system solution suitable for use in a wide variety of military and commercial applications. Scalable from 24 KW to 72 KW, the PS-1872 includes three redundant 24 KW sub-rack modules. Each sub-rack module contains up to twelve 2 KW modules in an N + 1 redundant configuration.
For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.
Features
- Fully protected for over load, short circuit, over voltage, over temperature, and input phase fail
- Meets all MIL-STD 461D / EN 55024 Class A and Class B EMI requirements
- Redundant cooling liquid from independent chillers
- Up to 72 KW total output power
- User-friendly operation, optimized for service
Specifications
- Altitude (operating): 15,000 ft. per MIL-STD810F Method 500.4
- Controls: Power on/off via switch or via remote control, Indicator lights for each module, Indicator lights identify each phase, output status, and output on/off, Output voltage and current monitoring via analog meter
- Efficiency: > 89%
- EMI: Per MIL-STD-461D
- ESD: EN61000-4-2 Level 3
- Fast transient: EN61000-4-4 Level 3
- Fungus: Per MIL-HDBK-454A Guideline 4
- Hold-up time: > 16 ms
- Humidity: 95% RH at 35 °C per MIL-STD-810F Method 507.4
- Input voltage: 380 VAC ± 10% line-to-line 3 phase star connection or 440 VAC ± 10.0% per MIL-STD-1399 (navy) Section 300A
- J1 input connector: MS3102E-4P
- J2 output connector: MS3102E-4S
- J3 220 VAC input: D38999-24WC98PN
- Mechanical shock: Half-sine 11 ms duration, 20 g peak per MIL-STD-810F, Method 516.5, Process 1
- Output voltage & current: 325 Vdc 225 A
- Power factor: 0.99 typical
- Ripple & noise: 3.2 V max. p-p
- Salt fog: Per MIL-STD-810F Method 509.4
- Size: 19 in. x 24-U x 31 in. (W x H x D)
- Soft start: Initial inrush current limit
- Storage: –30 °C to 71°C
- Surge: EN61000-4-5 Level 3
- Total harmonic distortion: < 5%
- Transient load: ± 3% max. for 50% step load
- Vibration: Per MIL-STD 810F, Method 514.5, Category 10 equipment
- Weight (with all sub-racks and modules): 220 Kg
Applications
- None Available
Aliases