DIGITAL POWER Industrial Partner

PS2156 - Digital Power PS2156 Power Supply - 48V/12.5A 600W Cassette I2C...

larger image

Request Quote
For Price
Part Number:
PS2156
Model Number:
PS2156
Make:
DIGITAL POWER
Lead Time:
Available
Qty In Stock:
Available

Digital Power PS2156 Power Supply - 48V/12.5A 600W Cassette I2C option available, AC Wide Input Range Power Supply with Battery Support Simple Type: Power Supply

The Strong Box Series of 600-1500 Watt Front End Power Supply Modules and Mating 1U High / 19” Rack Mount Chassis offer the ideal solution to your redundant power requirements. These hot-swap / redundant power modules offer a full complement of status & control signals required by today’s leading edge systems. Features Include:

Download the datasheet (PDF)

For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.

Features

  • 48 - 56VDC output
  • 600 - 1500W power modules
  • Active load current share
  • Includes OR-ing diode for N+1 parallel operation
  • International regulatory approvals
  • RoHS compliant
  • Univeral AC input with PFC

Specifications

    General
  • AC Input Voltage: 90-264VAC, 47-63Hz
  • AC OK: LED Indicator
  • Auxillary Output: 5V / 30mA per module
  • Conducted Immunity: EN61000-4-6, 0.15-800MHz, 10V, 80% AM
  • Cooling: 2 Ball Bearing Fans Per Module
  • Current Share: Single Wire
  • DC Fail: Active Low - Fail
  • EFT / Bursts: EN61000-4-4, ±2KV
  • Electrostatic Discharge: EN61000-4-2, ±4KV Contact / ±8KV Air
  • EN55022: Class B (In Rack Mount Chassis)
  • Fluctuations & Flicker: EN61000-3-3
  • Harmonics: EN61000-3-2 Level D
  • Hold-up time: > 20msec (Full Load & 110 VAC)
  • Humidity: <95% Non-Condensing
  • Initial Setting Accuracy: ± 1%
  • Input Fuse: Single 10A / 250 VAC Fast Action Fuse
  • Input Line Protection: Per Module
  • Inrush Current: <50A @ 250 VAC (Cold Start)
  • Line Regulation: ± 0.2%
  • Load Regulation: ± 0.5%
  • MTBF: >375k Hours (BellCore Gb B332 @ 50C)
  • Operation Temperature: -5 ~ +50C, derate 2.5%/C up to 70C max
  • Over-Temp Warning: Open Colletor, Active Low
  • Over-voltage Protection: 110-125%
  • Overload Protection: 115-125% of Module rating
  • Power Factor Correction: >0.95 for EN61000-3-2 Class D
  • Radiated Susceptibility: EN61000-4-3, 26-1000MHz, 10V/M, 80% AM
  • Remote Inhibit: Active Low - Off
  • Remote sense: Compensates for < 250mV Drop
  • Ripple @ Noise (V1): 150mv pk-pk max per Module (20MHz)
  • Safety Approvals: UL/cUL 60950, EN60950, CE Mark (LVD)
  • Shock & Vibration: EN300 019-2-1, 2, 3
  • Storage Temperature: -40 ~ +85C
  • Surges: EN61000-4-5, ±2KV Line-Earth, ±1KV Line-Line
  • Temperature Protection: Internal Heatsink >90C (auto-recovery)
  • Transient response: <5%, recovers in < 0.5msec
  • Turn-on Delay: <2sec
  • Voltage Adjustment: ± 5%
  • Voltage Dips: EN61000-4-11, 95% Dip & 10ms, 30% Dip & 500ms
  • Voltage Interruptions: EN61000-4-11, 95% Reduction, 5s

 

Applications

  • None Available

Aliases