DIGITAL POWER Industrial Partner

UPF600-148 - Digital Power UPF600-148 Power Supply - Medical and ITE Grade...

larger image

Request Quote
For Price
Part Number:
UPF600-148
Model Number:
UPF600-148
Make:
DIGITAL POWER
Lead Time:
Available
Qty In Stock:
Available

Digital Power UPF600-148 Power Supply - Medical and ITE Grade 600 Watt Dual Output Power Switcher, Output Current 12.5 A Simple Type: Power Supply

The Digital Power Open Frame Series switching power supplies incorporate advanced component and circuit technologies to deliver the smallest 600 watt switchers in the industry. Designed to meet 1U height considerations, the devices’ U-Frame packages measure only 6.80 x 3.86 x 1.50”. Each model offers universal AC input (85–265 VAC) with active power factor correction (PFC), optional 48 VDC input, flexible output configurations, and compliance with worldwide safety and EMC standards.

Download the datasheet (PDF)

For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.

Features

  • 350–600 watts
  • Digital PFC for accurate input power metering and inrush current control for AC and DCsystems
  • High efficiency operation of up to 90%
  • I²C interface provides for firmware uploads, status monitoring, and product data retrieval
  • L x W x H: 6.80 x 3.86 x 1.50” (17.27 x 9.80 x 3.81cm)
  • Low profile 1U height
  • O’ring diodes/FETs for redundant operation
  • Optional 36–72 VDC input range
  • Power density of 22 W/in.3
  • Single wire current share
  • Universal AC input (85–265 VAC) with active PFC for EN6100-3-2 compliance

Specifications

    General
  • AC Fail: ACTIVE low 10 ms before loss of power with internal 3.3V reference voltage
  • AC Input Voltage: 85–265 VAC wide range
  • Auxiliary Output: 5 V / 500 mA
  • Conducted Immunity: EN61000-4-6, 0.15-800 MHz, 10V, 80% AM
  • Cooling: 300 W free convection cooling, 600 W forced air cooling
  • Current Share: Single wire, ±10% accuracy
  • EFT/Bursts: EN61000-4-4, ±1 KV
  • Electrostatic Discharge: EN61000-4-2, ±4 KV contact / ±8 KV air discharge
  • Fluctuations & Flicker: EN61000-3-3
  • Hold-up time: 16 ms @ full load
  • Humidity: Up to 95% RH non-condensing
  • Initial Setting Accuracy: ± 0.5% maximum
  • Input Inrush Current: < 50 A @ 250 VAC cold start
  • Input Line Protection: 10 A 250 VAC SLO BLOW IEC type
  • Input Reflected Ripple: FCC 68 part 15 Class B with external line filter
  • Line Regulation: ± 0.1% for Vin (min.) to Vin (max.)
  • Load Regulation (V1): ± 0.5% maximum
  • Load Regulation (V2): ± 5% maximum V3 and V4: ±5% maximum
  • Min Load Requirement: None
  • MTBF: >300,000 hours
  • Operating Temperature: –25°C to 50°C (–13°F to 122°F); De-rate of 2.5% per 1°C to 70°C (34°F to 158°F)
  • Over-voltage Protection: 120% typical latched shut-down
  • Overload Protection: Hiccup mode, 110% typical of maximum output load
  • Power Factor Correction: >0.98 typical @ 110/220 VAC input @ full load
  • Power OK: ACTIVE low and ACTIVE high with internal 3.3V reference voltage, indicates when main output volage drops more than 10%
  • Radiated Susceptibility: EN61000-4-3, 80 –1000MHz, 3 V/m, 80% AM
  • Remote Inhibit: ACTIVE low-output shut down
  • Remote sense: Compensates for < 500 mV drop
  • Ripple/noise: 1% p-p maximum
  • Safety Approvals: IEC/EN/UL/cUL 60950-1 & 60601-1, CE Mark (LVD)
  • Shock & Vibration: 0.75 G peak 5 Hz – 500 Hz
  • Storage Temperature: –25°C to 95°C (–13°F to 203°F)
  • Surges: EN61000-4-5, ±2 KV line-earth, ±1 KV line-line
  • Temperature Protection: Shutdown (internal heat-sink temp. >95°C/203°F) with auto recovery
  • Transient response: ±5% max. deviation for load change of 25% to 75% at slew rate of 1A/usec, recovery time to 1% within 500 usec
  • Turn-on Delay: 1 sec. maximum
  • Voltage Dips: EN61000-4-11, 30% dip for 10 ms, 60% dip for 100 ms
  • Voltage Interruptions: EN61000-4-11, 95% reduction for 5,000 ms

 

Applications

  • None Available

Aliases

  • None Available